Close Go back Collapse all sections
Process Data set: Sieving and crushing plant ; Washed Blended coal ; Bituminous coal and anthracite coal ; Lump coal is washed, and fine coal is not washed ; 1.2~10 million t/a; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Sieving and crushing plant ; Washed Blended coal ; Bituminous coal and anthracite coal ; Lump coal is washed, and fine coal is not washed ; 1.2~10 million t/a; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所述工业过程用于筛分和破碎厂操作,用于处理混合煤,特别是烟煤和无烟煤。块煤经过洗涤过程以去除杂质,而细煤则不洗。该过程适用于处理从120万到1000万吨不等的大规模煤炭加工操作。另外,该过程包括了末端排放污染颗粒管理技术,如布袋过滤器、旋风除尘、组合除尘、喷雾系统和直接排放,以对抗PM2.5到PM10颗粒物排放。这些技术对于减少煤炭加工设施的空气污染至关重要。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Hard coal based fuels
General comment on data set the Technical of end-of-pipe management technology for pollution Standard coalisBag filter,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Standard coalisBag filter,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 07f3be96-12e9-482d-841a-a1b275d0a5a9
Date of last revision 2024-04-15T22:03:15.780957+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=07f3be96-12e9-482d-841a-a1b275d0a5a9&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Raw materials 1000.0 kg1000.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0375 kg0.0375 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isCombined dust removal,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.075 kg0.075 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0825 kg0.0825 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isCyclone dust removal,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.1125 kg0.1125 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSpray,Its Technical efficiency of end-of-pipe management85
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.75 kg0.75 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)