Close Go back Collapse all sections
Process Data set: Fine coal, wet coke quenching, screening, transfer, gas cleaning, etc. ; Coke ; Coking coal ; Top loading ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Fine coal, wet coke quenching, screening, transfer, gas cleaning, etc. ; Coke ; Coking coal ; Top loading ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该工业过程涉及从顶装炼焦煤生产焦炭的炼焦过程。这个过程包括精煤处理、湿熄焦、筛分、转运和煤气净化。所得焦炭用于包括冶金工业在内的各种应用,用作还原剂和热能源,以生产钢材。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Hard coal based fuels
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1000.0 * 1.0 kg (Mass)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID bc186e37-f0e0-498f-b403-9de3b9038389
Date of last revision 2024-04-15T22:09:55.036709+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=bc186e37-f0e0-498f-b403-9de3b9038389&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 9.1E-5 kg9.1E-5 kg
General comment the Technical of end-of-pipe management technology for pollution ammoniaisOthers (ammonium sulfate method),Its Technical efficiency of end-of-pipe management95
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 9.695E-5 kg9.695E-5 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.00521 kg0.00521 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisDirect discharge,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.00759 kg0.00759 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management99
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0176 kg0.0176 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisDirect discharge,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0197 kg0.0197 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.759 kg0.759 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,Its Technical efficiency of end-of-pipe management0
Product flow
Energy carriers and technologies / Hard coal based fuels 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 1.97 kg1.97 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 650.0 m3650.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Product flow
Materials production / Inorganic chemicals 980.0 m3980.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))