Close Go back Collapse all sections
Process Data set: Papermaking ; Corrugated base paper ; Semi-chemical pulp ; Mechanical paper copying ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Papermaking ; Corrugated base paper ; Semi-chemical pulp ; Mechanical paper copying ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集涉及使用半化学浆机械法生产适用于所有规模操作的瓦楞原纸的造纸过程。数据包括造纸过程中用于处理化学需氧量(COD)形式污染的末端处理技术的详细信息。描述的技术有化学混凝、好氧生物处理和浮选分离,这些技术单独使用或各种组合使用以实现高COD去除效率百分比。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Paper and cardboards
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisFloating separation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisFloating separation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 97954c20-c1f2-47c6-9bfd-7d7b10227c5f
Date of last revision 2024-04-15T22:08:17.595281+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=97954c20-c1f2-47c6-9bfd-7d7b10227c5f&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
41000.0 41000.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.3158000000000012 kg1.3158000000000012 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + aerobic biological treatment + chemical coagulation,Its Technical efficiency of end-of-pipe management96.94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.2575 kg2.2575 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + aerobic biological treatment + floating separation,Its Technical efficiency of end-of-pipe management94.75,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.2575 kg2.2575 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisFloating separation + aerobic biological treatment + chemical coagulation method,Its Technical efficiency of end-of-pipe management94.75,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.7625 kg3.7625 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management91.25,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.87 kg3.87 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisFloating separation + aerobic biological treatment + floating separation,Its Technical efficiency of end-of-pipe management91,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.45 kg6.45 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisFloating separation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)